Basic Thermocouple (Type 1)

General Purpose Thermocouples

A simple welded junction thermocouple made from bare wires or insulated cable with a welded junction. Various wire sizes are available with the junction welded in an inert argon atmosphere. Type 1 assemblies are available in thermocouple types K, T, J, N, E, R, S, B, G, C and D.

Basic Thermocouple Enquiry Form

1. Thermocouple Type
2. Style Number

3. Overall Length

 mtrs*
4. Optional Thermocouple Plug

5. Quantity Required

Contact Details

Company Name


Your Name


Title/Dept.


Email


Telephone


Additional Information

If your enquiry is for more than one style of sensor, please email us with your requirements or use the box below



Send Enquiry  

We will only use your email address to contact you. We will never give your email address to 3rd parties and we do not sell data on to any other company. We prefer to concentrate on making quality temperature related products. Our privacy policy can be viewed here.

Frequently Asked Questions

  • What is a thermocouple and how does it work?
    A thermocouple is a type of temperature sensor that generates a voltage when two different metals are joined at one end and exposed to a temperature difference between the "hot" junction (where the temperature is measured) and the "cold" junction (the reference point). This voltage is then measured to determine the temperature at the hot junction.
  • How do I choose the right thermocouple for my application?
    The ideal thermocouple depends on factors such as temperature range, accuracy, termination type, mounting requirements and environmental conditions. We offer a variety of thermocouples with different sheath materials, constructions, terminations, and temperature ratings to meet your needs. If you need specific advice, our engineers are happy to assist!
  • What is the maximum temperature rating of your thermocouples?
    Our thermocouples are designed to handle a wide range of temperatures with some mineral insulated thermocouples able to withstand temperatures up to 1400ºC and ceramic sheathed thermocouples going even higher to 1600ºC. Each product listing includes the maximum temperature rating, so you can choose the best thermocouple for your application.
1 Thermocouple Type Temperature Range (continuous) Temperature Range
(short term)
K Nickel Chromium vs
Nickel Aluminium
0°C to +1100°C -180°C to +1350°C
T Copper vs Constantan -185°C to +300°C -250°C to +400°C
J Iron vs Constantan +20°C to +700°C -180°C to +750°C
N Nicrosil vs Nisil 0°C to +1100°C -270°C to +1300°C
E Nickel Chromium vs Constantan 0°C to +800°C -40°C to +900°C
R Platinum - 13% Rhodium vs
Platinum
0°C to +1600°C -50°C to +1700°C
S Platinum - 10% Rhodium vs
Platinum
0°C to +1550°C -50°C to +1750°C
B Platinum - 30% Rhodium vs
Platinum 6% Rhodium
+100°C to +1600°C +100°C to +1820°C
G Tungsten vs
Tingsten 26% Rhenium
+100°C to +1600°C +20°C to +2320°C
C Tungsten - 5% Rhenium vs
Tungsten 26% Rhenium
+20°C to +2300°C 0°C to +2600°C
D Tungsten - 3% Rhenium vs
Tungsten 26% Rhenium
0°C to +2100°C 0°C to +2600°C
Temperature ranges refer to the thermocouple type.
The temperature range of the sensor may deviate from the above,