RTD Cable - Fibreglass Insulated with Stainless Steel Braid
RTD Resistance Thermometer Cables
|
|||||||
Fibreglass Insulated with St./St. Braid
Cores of stranded copper conductors. Cores double glass lapped, glass fibre braided and varnished. Cores bunched together, glass fibre braided overall and impregnated with silicone varnish. Stainless Steel braid overall. |
|||||||
Stock Number | RF37 | RF47 | RF67 | ||||
Conductor Style | Stranded | ||||||
No. of Strands / Strand Diameter (mm) | 7/0.2 | 7/0.2 | 7/0.2 | ||||
Total Area (mm2) | 0.22 | 0.22 | 0.22 | ||||
Total AWG (S = Stranded) | 24S | 24S | 24S | ||||
Insulation | Fibreglass | ||||||
Number of Cores | 3 | 4 | 6 | ||||
Laid Flat or Twisted | Twisted | ||||||
Screen | Yes | ||||||
Insulation | Fibreglass | ||||||
Insulation Rating (ºC) |
Continuous | +480 | |||||
Short Term | +540 | ||||||
Colour Coding | Yes | ||||||
Physical Properties |
Abrasion Resistance | Good | |||||
Moisture Resistance | None | ||||||
Typical Weight (Kg/100m) excl reel |
2 | 3 | 4 | ||||
Diameter under Armour (mm) | — | ||||||
Diameter over Armour (mm) | — | ||||||
Overall Diameter | 3 | 4 | 5 | ||||
Popular Order Codes | RF37, RF47, RF67 |
||||||
Notes All dimensions are approximate |
Above 180°C the integrity of the cable is maintained to the upper insulation limit provided the cable is not flexed particularly when cold. |