Need a quote or advice?

Contact one of our experienced engineers

International: +44 1895 2522222
Call TC
TC Ltd for Temperature Measurement & Control

RTD Cable - MICA Glass / XLPE / LS0H Insulated RTD Cable

RTD Resistance Thermometer Cables

  • The following leads and cables are suitable for connecting to our range of Platinum Resistance Thermometer assemblies. Some are quite small and are ideal for extending out of an assembly pot seal but can be unwieldy for longer runs. Others are more robust, offer greater mechanical strength and are more suited for extending out of an assembly connection head or for use in connecting to junction boxes.
  • Whilst some of these cables are suited for longer cable runs, our range of single and multipair instrumentation cable may be more suitable for such applications.
MICA Glass / XLPE / LS0H with Screen
Cores of stranded copper conductors, MICA glass taped and XLPE insulated. Cores bunched and screened with Mylar® aluminium tape and drain wire. LS0H sheathed overall.

MICA Glass / XLPE / LS0H with Screen and Armour
Cores of stranded copper conductors, MICA glass taped and XLPE insulated. Cores bunched and screened with Mylar® aluminium tape and drain wire. LS0H sheathed. Steel wire armoured and LS0H sheathed overall.

Stock Number RM37 RM67 RM37/SWA RM67/SWA
Conductor Style   Stranded
No. of Strands / Strand Diameter (mm)   7/0.3 7/0.3 7/0.3 7/0.3
Total Area (mm2)   0.5 0.5 0.5 0.5
Total AWG (S = Stranded)   20S 20S 20S 20S
Insulation   MICA and XLPE MICA and XLPE
Number of Cores   3 6 3 6
Laid Flat or Twisted   Twisted Twisted
Screen   Yes Yes
Insulation   LS0H LS0H
Insulation
Rating (ºC)
Continuous   -30 to +75 -30 to +75
Short Term  
Colour Coding   Yes Yes
Physical
Properties
Abrasion Resistance   Good Good
Moisture Resistance   Very Good Very Good
Typical Weight (Kg/100m)
excl reel
  10 13 32 50
Diameter under Armour (mm)   8 11
Diameter over Armour (mm)   10 13
Overall Diameter   8 11 13 16
Popular Order Codes

RM37, RM67

RM37/SWA, RM67/SWA

Notes



All dimensions are approximate
Free of Halogens. Round Section. Rejects electromagnetic and
electrostatic interference.
Free of Halogens. Round Section. Rejects electromagnetic and
electrostatic interference.
Armoured for mechanical strength.

Enquiry Form - RTD Cable

1. Stock Number

2. Quantity Required