Need a quote or advice?

Contact one of our experienced engineers

International: +44 1895 2522222
Call TC
TC Ltd for Temperature Measurement & Control

IECEx Approved Spring Loaded Thermocouples for the Petrochemical, Oil and Gas Industries

with a choice of Terminal Heads

Supplied with an IP68 terminal head, these IECEx approved spring loaded semi rigid thermocouples are ideal for installation in thermowell pockets via the threaded flameproof extension piece. Suitable for service temperatures up to 1250°C (minimum stand-off lengths shown on here must be observed).
  • A wide range of protection concepts are available for use in Zones 0, 1 & 2. See table below for details
  • The following thermocouple types are available: K, T, J, N, E, R, S and B
  • For stand-off requirements (Temperature classification T6-T1), see here
  • Available in 4.5m, 6.0mm & 8.0mm diameters in a wide range of sheath materials
  • A floating output with high insulation resistance is given via an insulated measuring junction
  • These sensors can be UKAS calibrated
  • Spring loaded thermocouple insert with wide choice of process connections
Available with the following approvals:

Protection Type Description Zone
Ex nA IIC Gc Non-Sparking (Gas) 2
Ex d IIC Gb Flameproof (Gas) 1
Ex ia IIC Ga / IIIC Da Intrinsically Safe (Gas/Dust) 0/20
Ex ib IIC Gb / IIIC Db Intrinsically Safe (Gas/Dust) 1/21
Ex tb IIIC Db Enclosure (Dust) 21
Ex tc IIIC Dc Enclosure (Dust) 22



Enquiry Form

1. Thermocouple Type

2. Protection Concept

Your chosen concept is:

Ex d Flameproof/Explosion Proof – Category 2, Zones 1,2 (Gas)
• Ex d IIC T6...T1 Gb Ta = –40°C to 60°C
• Standard EN IEC 60079-1 refers
• Designed to contain an explosion and quench the flame
• Sensors incorporate a suitable heavy duty enclosure or threaded fitting with tight seals
Your chosen concept is:

Ex e Increased Safety – Category 2, Zones 1,2 (Gas)
• Ex e IIC T6...T1 Gb Ta = –40°C to 60°C
• Standard EN IEC 60079-7 refers
• Design ensures no arcs, sparks or hot surfaces that could ignite an explosive mixture with a minimum IP54 enclosure rating
• Sensors incorporate a suitable heavy duty enclosure or threaded fitting with tight seals
Your chosen concept is:

Ex ia Intrinsically Safe – Category 1, Zones 0,1,2 (Gas) & 20,21,22 (Dust)
Available for assemblies with Stainless Steel Terminal Heads
• Ex ia IIC T6...T1 Ga Ta = –40°C to 60°C
• Ex ia IIIC T80°C…T440°C Db
• Standard EN IEC 60079-11 refers
• Designed to limit the energy of arcs or sparks that could potentially ignite an explosive mixture
• Sensors used in this area must be wired through a suitably approved barrier
• Optional approved 4 to 20mA transmitters available
Your chosen concept is:

Ex ib Intrinsically Safe – Category 2, Zones 1,2 (Gas) & 21,22 (Dust)
Available for assemblies with Die Cast Alloy Terminal Heads
• Ex ib IIC T6...T1 Gb Ta = –40°C to 60°C
• Ex ib IIIC T80°C…T440°C Db
• Standard EN IEC 60079-11 refers
• Designed to limit the energy of arcs or sparks that could potentially ignite an explosive mixture
• Sensors used in this area must be wired through a suitably approved barrier
• Optional approved 4 to 20mA transmitters available
Your chosen concept is:

Ex nA Non-Sparking – Category 3, Zone 2 (Gas)
• Ex nA IIC Gc T6…T2
• Standard EN IEC 60079-15 refers
• No arcs, sparks or hot surfaces
Your chosen concept is:

Ex tb Enclosure – Category 2, Zones 21, 22 (Dust)
• Ex tb IIIC T80°C…T440°C Db
• Standard EN IEC 60079-31 refers
• Protects against combustible and conductive dusts, rugged tight enclosures are used
Your chosen concept is:

Ex tc Non-Sparking – Category 3, Zone 22 (Dust)
• Ex tc IIIC T85°C...T450°C Dc
• Standard EN IEC 61241 refers
• Protects against combustible dusts
• Sensors incorporate a suitable heavy duty enclosure with IP6X seal
3. Sheath Material

4. Sheath Diameter

5. Overall Sheath Length ( 'L')

 mm*
6. Types of Sensing Junction

7. Terminal Head

8. Extension Piece Length ( 'L1')

 mm*
9. Process Thread

10. Optional (Rotating Union) Fitting

11. Optional 4 to 20mA Transmitter

12. Quantity Required

Contact Details

Company Name


Your Name


Email


Telephone


Additional Information

If your enquiry is for more than one style of sensor, please email us with your requirements or use the box below



Send Enquiry